DOUBLE CASE PD FLOW METERS
Inquire Now   Inquiry Form Technical Documents   Service Manuals Technical Documents   Technical Documents

 

 
  Double Case PD Flow Meter  
 

Double Case Positive Displacement Meters have been specially designed to eliminate the effect of line pressure on the metering accuracy. Available in a wide range of flow capacities, the Double Case design ensures a high accuracy along with ease of servicing of "in-situ'.
Download Literature in pdf format.

DESIGN FEATURES

  • Safe & rugged construction.
  • Low pressure drop.
  • Step-less calibration adjustment.
  • Unique wear compensating vane design for sustained accuracy over wide flow range.
  • Easy access to measuring chamber without need of removing the outer casing ensures minimum service downtime.
  • Mechanical or electronic readout.
  • Double Case design prevents distortion of measuring chamber due to line pressure fluctuations & ensure high accuracy.


PRINCIPLES OF OPERATION

The Double Case Flow Meter consists of a measuring chamber which is bolted inside an outer casing. The measuring chamber consists of a Flow Meter body, rotor with vane blades & two internal covers. Fixed to the outer casing is a manifold, an outer end cover, & a Calibrating Mechanism (or a Pulse Transmitter depending upon the requirement of a electronic readout). The rotor spindle transmits the drive through a pressure tight seal in the outer cover to the calibrating mechanism (or Pulse Transmitter), which calibrates the meter output for a corrected counter readout. All mechanical Flow Meters are fitted with Veeder Root mechanical counters.

The product enters the Flow Meter measuring chamber through the manifold inlet & at the same time fills up the space between the outer casing & the measuring chamber. This effectively 'pressure balances' the measuring chamber & prevents distortion due to line pressure fluctuations to ensure a high metering accuracy. The separate manifold design further enhances performance & accuracy by preventing distortion due to pipe line stresses. The liquid on entering the measuring chamber causes the rotor to revolve by exerting pressure on the vane blades. The proximity of the rotor to the body forms an efficient seal while the profile of the body ensures that the vane blades are guided through the measuring crescent. The vane blades divide the liquid into segments & each revolution of the rotor displaces four such segments. The rotor spindle transmits the drive through a Calibrating Mechanism or Pulse Transmitter. The measuring chamber, for ease of servicing, can easily be removed from the outer casing by only removing the front cover.


APPLICATIONS

  • Tank truck & rail wagon gantry filling.
  • Refineries.
  • Microprocessor based automation, remote control & data acquisition systems.


MATERIALS OF CONSTRUCTION
 

Outer Casing & Cover

  • Cast Steel ASTM A 216 WCB.

Meter Body

 

  • Cast Iron (standard).
  • Cast Steel ASTM A 216 WCB (optional).
  • Stainless Steel AISI 316 (optional).

Rotor

 

  • Aluminium Alloy LM 25 (standard).
  • Stainless Steel AISI 316 (optional)

Vanes

  • Resin impregnated Morganite CY10C.

Bearingss

  • Bearing Steel (standard).
  • Stainless Steel AISI 440 C (optional)

Seals

  • Nitrile (standard).
  • Viton (optional).

Other Wetted Parts

  • Stainless Steel AISI 304 & AISI 410.

Manifold

  • Cast Steel ASTM A 216 WCB (for TLD 01 / 02 / 03 / 04).
  • Carbon Steel Fabricated (for TLD 05 / 06 / 07 / 08 /
    09 / 10).



SPECIFICATION
 

Type

  • Positive displacement rotary vane.

Sizes

 

  • 65 mm (Model TL 01 / 02).
  • 80 mm (Model TL 03 / 04 / 05 / 06).
  • 100 mm (Model TL 07 / 08 / 09 / 10).
  • 150 mm (Model TL 11 / 12).
Flow Range
  • 114-1135 Ipm (TL 01 / 02).
  • 136-1364 Ipm (TL 03 / 04).
  • 205 - 2046 Ipm (TL 05 / 06 ).
  • 227 - 2273 Ipm (TL 07 / 08).
  • 295-2955 Ipm (TL 09 / 10 / 11 / 12).

End Connections

  • ASA 150 FF (standard).
  • ASA 150 RF (optional).

Meter Hand Of Discharge

 

  • Left hand entry, right hand discharge (For even Meter
    model nos.).
  • Right hand entry, left hand discharge (For odd Meter
    model nos.).

Drive

  • Positive gear train.


Counter

  • Mechanical - 5 digit reset, 8 digit-non reset totaliser,
    weatherproof Veeder Root 7887.
  • Electronic - 8 digit reset, 8 digit non-reset totaliser,
    weatherproof.
  • Electronic - 5 digit reset, 8 digit non-reset totaliser,
    flameproof.


Accuracy
  • Better than +/- 0.10% (in accordance with IS:2801-1967 & Manual of Weights & Measures Vol I Schedule VII Part IV-1974).

Repeatability

  • Better than +/- 0.02%.
Rangeability
  • 100% to 10% of maximum flow range.
Maximum working pressure
  • 10.54 kg/cm2.

Temperature
  • Up to 70o C (standard).
  • Up to 200o C (optional).

Viscosity
  • 0.5 CST to 200 CST (standard).
  • (For liquid viscosity above 200 CST, consult factory).

Pulse Output (optional)
  • 100 PPR, TTL compatible.
 
Inquire Now   Inquiry Form Technical Documents   Technical Documents
 
News Update:
View All News  View All News
 

Kamanwala Chambers,
4th floor, Sir P. M. Road, Fort,
Mumbai 400 001, INDIA

Tel : +91 (22) 67477900
Fax : +91 (22) 67477901
Email : contactus@telgroup.com
Copyright © TEL Group I SiteMap Design & Developed by Iniquus